● Electro-Static discharge,Surface resistance <109Ω
● Easy assembly: Chain links openable along inner or outer radius from both sides
● High strength: large pin/bore and crossbar with high locking force
● Long service life: lateral sliding surfaces design
● For long unsupported lengths: strength and double stop-dog design
● Universal connection: many mounting options with or without strain relief
● Inner height:18 mm
● Inner width:38-125 mm
● Bend radius:38-250 mm
● Link pitch:40 mm
● Inner height:25 mm
● Inner width:38-125 mm
● Bend radius:55-250 mm
● Link pitch:46 mm
● Inner height:35 mm
● Inner width:50-150 mm
● Bend radius:63-250 mm
● Link pitch:56 mm
● Inner height:45 mm
● Inner width:75-175 mm
● Bend radius:75-300 mm
● Link pitch:67 mm
C02E ESD universal cable carriers for a wide range of
applications, easy and versatile assembly combined with
ruggedness - high strength paired with quieter motion -
long cable life and many mounting options.
Multiple opening methods
Flammability Class UL94 HB
CE certification
RoHS certification
Universal cable carriers | Part No. | Inner width Bi [mm] | Outer width Ba [mm] | Inner height Hi [mm] | Outer height Ha [mm] | Bend radius R [mm] | Unsupported length [m] |
C02E.18 | 38-125 | 54-141 | 18 | 28 | 38-150 | ≤1.8 | |
C02E.25 | 38-125 | 54-141 | 25 | 35 | 55-250 | ≤2.4 | |
C02E.35 | 50-150 | 66-194 | 35 | 50 | 63-250 | ≤2.8 | |
C02E.45 | 75-175 | 95-270 | 45 | 64 | 75-300 | ≤3.7 |
In order to ensure that the chain is functioning properly and to avoid damage to the cables or hoses, the following principles must be observed when laying cables or hoses:
▊ This minimum clearance would be 10% for electrical round cables, 20% for hydraulic hoses. | |
▊ In order to reduce the possible friction, avoid pipes with different skin materials such as cables or hoses.(eg: cable and hydraulic hoses) | |
▊ In applications where multiple cables and hoses are used, in order to avoid mutual friction between them, it is preferable to place them in a suitable separate space and separate them from each other with a spacer. If there are no conditions to achieve, make sure there is enough space between them to avoid mutual friction (H<D). | |
▊ The cables or hoses are laid in a symmetrical manner according to their diameter and weight. The largest and heaviest cables are placed on the outside of the section and the small and light cables are placed on the inside. |
● The separator separates inside space of the chain to protect cables, oil hoses, gas hoses, etc.
● Separator with high strength, can be firmly fitted in carriers
more● Aluminum alloy, surface anodized
● The tiewrap elements can move within the guide slot
more● Use with vertical separators to arrange the space in the cable chain in layers up and down.
● The vertical separators can move freely along the horizontal direction.
● Aluminum alloy, surface anodized
● The tiewrap elements can move within the guide slot
● Available as an individual component
● Can be clipped into C-profile bracker
moreBL bellows is suitable for use in general mechanical applications, The good anti-freezing ability and self-extinguishing properties can be used in automotive industries. The bellows keep high impact resistance in ...
more713
● General machinery
● Construction machinery
● Printer and plotter
● Handling machines
● Plastic handling machines
● Semi-conductor machines
● Glass machines
● Limited long travel applications
▊DURAMOV® Cable Chain Finder[V1.1] is based on the analysis and calculation of a large number of test data in CSB® laboratory. You can calculations filler and installation data by entering parameters such as cables, gas tubes, oil tubes and installation data, The system will analyze your design data and finally output the adaptation cable chains.
▊Because the system calculate and analyze based on lab data, it can't exactly meet the ractual use requirements absolutly. The system data verification has certain limitations; CSB® recommends that the cable chains must be tested again to verify whether it meets the actual use requirements.
▊DURAMOV® Cable Chain Finder output data information is only for design reference, and can not be used as the final standard for determining the cable chains conformity, If you have any questions, please contact CSB® sales engineers.
High flexible cables are designed for highly bending and continuous motion applications and used for cable chains, robots, auto-drive systems, etc ...
moreOpenable along inner or outer radius from both sides, large pin/bore and crossbar with high locking force
Inner height: 18 to 45mm
Inner width: 38 to 175mm
High strength and stable, long service life, openable along the both sides
Inner height: 32 to 80mm
Inner width: 50 to 200mm
Electro-Static discharge, surface resistance <109Ω, One-piece design, non-openable
Inner height: 07 to 15mm
Inner width: 07 to 50mm
Electro-Static discharge,Surface resistance <109Ω, Two-pieces design, openable along the outer radius
Inner height: 15 to 20mm
Inner width: 16 to 50mm
Electro-Static discharge,Surface resistance <109Ω, Two-pieces design, openable along the inner or outer radius
Inner height: 10 to 20mm
Inner width: 10 to 50mm